{"product_id":"35cfm-058km-110-115v-1-phase-refrigerating-dryer-fits-for-75hp-10hp-air-compressor-78919496","title":"35CFM 0.58KM 110-115V 1 Phase Refrigerating Dryer Fits for 7.5HP 10HP Air Compressor 78919496","description":"\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cspan style=\"color: #c00000; font-size: 18pt;\"\u003eFeatures:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eIndustrial Refrigerated Air Dryer with R134a Cooling System for Air Compressors – 35 CFM, 0.58 KW, 110V\/60Hz – Removes Moisture, Oil, Contaminants – Ideal for Workshop, Garage, Pneumatic Tools\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003ePowerful Moisture Elimination: Designed for 7.5 HP \u0026amp; 10 HP air compressors, this industrial-grade refrigerated air dryer efficiently removes water vapor, oil aerosols, and contaminants from compressed air, ensuring clean, dry airflow for pneumatic tools, spray painting, and CNC machines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eHigh-Performance Cooling with R134a Refrigerant: Equipped with an energy-efficient R134a cooling system (0.58 KW), this dryer maintains stable temperatures to prevent moisture buildup, even in high-demand workshop or garage environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eHeavy-Duty 35 CFM Capacity: Delivers 35 cubic feet per minute (CFM) of dry air, making it ideal for industrial, automotive, and manufacturing applications where moisture-free compressed air is critical.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eVersatile \u0026amp; Reliable for Multiple Uses: Perfect for sandblasting, laser cutting, HVAC systems, and woodworking. Operates at 115V\/60Hz and includes safety protections against overheating and voltage fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 12pt; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cspan style=\"color: #c00000; font-size: 18pt;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eType: Refrigerated Air Dryer\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eFlow Capacity: 35 CFM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eRefrigerant Type: R134A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eVoltage: 110-115V \/ 60HZ \/ 1 Phase\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003ePower: 0.58KM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eAir capacity: 1.0m³\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eWork pressure: ≤1.0Mpa\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eInlet temperature: ≤45℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eDew point temperature: 2-10℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003e\u003cspan style=\"color: #000000; font-size: 15pt;\"\u003eOperation method\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: 15pt;\"\u003e1. Check whether the refrigeration system pressure of the machine is normal. Check that the ball valve at the front of the automatic drainage valve is open.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: 15pt;\"\u003e2. Send the power supply to the control box, press ON\/OFF button switch ON button, machine contactor suction, compressor operation. At this time, the refrigerant low pressure gauge pointer should indicate that it is in the range of 60~85Psig. If the load exceeds this range, adjust it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; font-size: 15pt;\"\u003e3. After the compressor runs smoothly, the pressure of the refrigerant high pressure gauge rises to between 120 and 240psi.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003eWhen the high pressure of the refrigerant is higher than this range, check whether the heat dissipation of the condenser is good, and whether the inlet temperature of the air compressor and the ambient temperature are too high. When the antifreeze switch is lower than 140Psig, the condensing fan stops running to increase the pressure to ensure the normal operation of the machine. If the machine is operated at low pressure for a long time, check whether the refrigeration system leaks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0px; color: #333333; font-family: Arial; font-size: 16px; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times; color: #000000; font-size: 15pt;\"\u003e4. Please turn off the air compressor before shutting down. After turning OFF the air compressor, press the ON\/OFF switch to turn off the power supply of the machine.\u003c\/span\u003e\u003c\/p\u003e","brand":"Saleyee","offers":[{"title":"Default Title","offer_id":49736761999619,"sku":"GT-78919496","price":1243.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0554\/8012\/3573\/files\/21198342109f6523b60f1509404d1d61.jpg?v=1790763810","url":"https:\/\/zntswholesale.com\/products\/35cfm-058km-110-115v-1-phase-refrigerating-dryer-fits-for-75hp-10hp-air-compressor-78919496","provider":"ZNTS Wholesale United States","version":"1.0","type":"link"}